Cold room regulations: F gas duties and food temperature control

Updated

Two rule sets land on a cold room: F gas rules on the refrigerant and who may touch it, and food law on the temperature you hold product at.

Get cold room quotes Two minutes of questions, then cold room installers quote your actual job. Free, no obligation.

Neither is optional, and both affect what you should be buying.

Who is allowed to install and service it

A company that installs, repairs, maintains or decommissions stationary refrigeration containing F gas for others must be certified by an approved body. gov.uk is blunt: "It is against the law to work with F gas if you don't have the correct certification" (gov.uk, company certification). Certification is renewed every 3 years; the certifying body may audit it.

Individuals need their own qualification as well as the company holding a certificate. For stationary refrigeration, air conditioning and heat pump systems, gov.uk sets out category 1 to category 4 certificates (gov.uk, qualifications). Category 1 covers all activities; the lower categories are limited by system charge or to leak checking without breaking into the refrigeration circuit.

One useful exception: a business servicing only its own equipment with its own employees does not need the company certificate, but the individuals still need their qualifications.

Ask for the company certificate number and the certifying body before work starts, and keep it. You will need it for your own records anyway, see below.

The leak checks that come with owning the room

Leak checking is the user's duty, not just the engineer's. How often depends on how much F gas the system holds, expressed as a carbon dioxide equivalent (gov.uk, checking for leaks):

Minimum F gas leak-check frequency by system charge (gov.uk)
System charge (CO2 equivalent)Minimum leak-check frequency
5 to less than 50 tonnesAt least once every 12 months
50 to less than 500 tonnesAt least once every 6 months
500 tonnes or moreAt least every 3 months, and automatic leak detection must be fitted
  • Fitting automatic leak detection lets you double the interval between checks.
  • Where detection is fitted, the detection system itself must be checked every year (every 6 years for electrical switchgear).
  • If a leak is found it must be repaired as soon as possible and the repair retested within a month.
  • gov.uk states that not having the right leak checks in place, or not fixing leaks, breaks the law and can attract a civil penalty.

The records you have to keep

If your equipment holds F gas equivalent to 5 tonnes of carbon dioxide or more, you must keep records for 5 years covering:

  • the quantity and type of gas at installation;
  • gas added during maintenance;
  • the dates and results of every mandatory leak check;
  • what was done to recover and dispose of gas.

Users and operators must also record the name, address and certificate number of any company used to install, service or decommission the equipment. The Environment Agency may ask to see the register during an inspection (gov.uk, F gas records).

Food temperature control

Separately from F gas, food law sets what you must hold product at. In England, Schedule 4 of the Food Safety and Hygiene (England) Regulations 2013 covers food likely to support the growth of pathogenic micro-organisms or the formation of toxins. Keeping such food at food premises above 8°C is an offence, subject to listed exemptions and defences.

Holding cooked or reheated food for service below 63°C is also an offence where that temperature is needed to control pathogens (legislation.gov.uk).

  • 8°C is a legal ceiling, not a target. Operators routinely set chill rooms colder to leave margin for door openings, warm loads and defrost cycles, and because a manufacturer's own storage instruction on the label can be stricter than 8°C.
  • The Schedule includes exemptions and time-limited defences, for example short display periods and unavoidable equipment defrost or breakdown. Read the Schedule rather than relying on a summary.
  • The other UK nations have their own food hygiene regulations. If you are not in England, check the ones that apply to you.
  • Nothing on this page is food safety advice. If you are specifying a room to hold a particular product, confirm the temperature with your own food safety adviser or your local environmental health team.

The practical effect on your quote: specify the temperature you must legally and commercially hold, and let the installer size the plant to hold it in your worst realistic conditions. See how the refrigeration system is chosen.

Get cold room installation quotes

Two minutes of questions, then cold room installers quote your actual job. Free, no obligation.

The room

What do you need?

Chill or freeze?

Freeze costs more: thicker panels, insulated floor, defrost, bigger plant.

  • Free, no obligation
  • Your details go to at most three installers
  • Takes about two minutes

Questions, answered directly

Does a cold room installer have to be F gas certified?

Yes, for work on your stationary refrigeration equipment. gov.uk requires the company, including sole traders, to be certified by an approved body to install, repair, maintain or decommission such equipment for others. Each individual must also hold their own F gas qualification. Working with F gas without the correct certification is against the law and can attract a civil penalty.

How often must a cold room be leak checked?

It depends on the charge. gov.uk requires checks at least every 12 months for 5 to under 50 tonnes CO2 equivalent, and at least every 6 months from 50 to under 500 tonnes. At 500 tonnes or more it is at least every 3 months, and automatic leak detection is also mandatory. Fitting leak detection doubles the permitted interval.

What temperature must a commercial chill room hold?

In England it is an offence to keep food likely to support pathogen growth above 8°C at food premises. Schedule 4 of the Food Safety and Hygiene (England) Regulations 2013 sets this, subject to its exemptions and defences. That is a legal ceiling: operators normally set colder, and a manufacturer's storage label can be stricter. Other UK nations have equivalents.

Sources

This site's own dataset, every figure quoted from its source and dated:

  • The median published figure in the Cold Room Installed Price Index is 4,000 GBP across 9 sources' own pages (range 2,330.99 to 6,500 GBP), read 11 November 2026.
  1. gov.uk, fluorinated gases (F gases)
  2. gov.uk, certification for companies working on equipment containing F gas
  3. gov.uk, qualifications required to work on equipment containing F gas
  4. gov.uk, checking F gas equipment for leaks
  5. gov.uk, record F gas in equipment you own or service
  6. legislation.gov.uk, Food Safety and Hygiene (England) Regulations 2013, Schedule 4 (temperature control requirements)

Get a price for your room, not a range off the internet.

Two minutes of questions, then cold room installers quote your actual job. Free, no obligation.

Get cold room quotes